Calibration
Calibration results: sensor numbers
What calibration frames have measured so far: gain, read noise, bias level, dark current, bad pixels and flats. Today that is my own S30 Pro only. Anything not measured yet says so.
How to read this
- Conversion gain is how many electrons one count in the file stands for. Read noise is the noise every frame has before any light, in counts and in electrons. Black level is the offset the camera adds to every pixel.
- Dark current is the signal the sensor makes on its own, which grows with temperature, so it always comes with one.
- Corner over center is how much dimmer a flat's corners are than its middle; 1.000 would be perfectly even.
- Each number has a marker saying how far it is proven: measured means it comes from our own frames. All markers.
The numbers
Numbers as of 2026-11-17, from sensors.json.
My own S30 Pro, telephoto camera
Seestar S30 Pro, telephoto camera, gain 200. Calibration pipeline, frames shot 2026-10-09: IR-cut, raw; Phone-screen bench, session 1: IR-cut, LP, Dark, raw, over Alpaca; Phone-screen bench, session 2: IR-cut, LP, Dark, raw, over Alpaca.
| Number | Calibration pipeline, frames shot 2026-10-09 | Phone-screen bench, session 1 | Phone-screen bench, session 2 | |
|---|---|---|---|---|
| Conversion gain, e⁻ per count | 0.0591 | 0.0591 to 0.0596 | 0.0588 to 0.0595 | measured |
| Read noise, counts | 17.25 | 17.7 to 17.9 | 17.9 to 18.0 | measured |
| Read noise, e⁻ | 1.02 | 1.05 | 1.06 | measured |
| Black level (bias offset), counts | not yet measured | 1111.5 to 1112.1 | 1112.3 to 1112.9 | measured |
| Dark current, e⁻/s | 0.84 at 33.5 °C | not yet measured | 0.57 at about 31 °C | measured |
| Bad pixels listed | 35,750 | not yet measured | not yet measured | measured |
| Flat, corner over center (IR-cut) | 0.941 raw, 0.999 after the masters | 0.944 to 0.951 | 0.945 to 0.951 | measured |
| Worst linearity error, 5 to 80 % of clip | not yet measured | 0.36 % | 0.20 % | measured |
| Readout, whole frame, ms | not yet measured | 38.4 | 38.4 | measured |
My own S30 Pro, wide camera
not yet measured. No calibration run of this camera has been landed yet.
Seestar S50
not yet measured. No calibration run of this camera has been landed yet.
Every scope sent in: the sensor census
not yet measured. Each calibration run will add one anonymous line of sensor numbers to a census, with no serial, place or name. This page will show only counts and spreads, and only once at least 5 different scopes are in it, so that no number says anything about one person's scope. Your own numbers come back to you alone, on your private result page.
What isn't here yet
- Other gain settings, the wide camera and the S50. The S50 path has only run on a simulated scope.
- Dark current at more than one temperature from a calibration run, so the temperature law can be checked.
- The census of everyone's scopes. It fills as calibration runs come in, and shows counts and spreads only.
Want your own scope's numbers? Send your calibration frames. They come back to you alone, through a private link.
More
- Calibration: what to send, what comes back, what has been checked.
- Improvising a Dynamic Calibration Pipeline: how the two bench sessions were shot.
- How calibration works: the math.